Air Cooled Distribution Transformer

It is desirable that the spaces between the coverings and the turns of the electrical winding be thoroughly impregnated and coated with the varnish and the varnish coating is then thoroughly cured to provide optimum insulating and thermal conducting properties as well as being imperviousness to moisture and sufficient strength to resist fracture of the coating.

Dry Type Varnish Impregnated (VPI) Distribution Transformer

Dry Type Varnish Impregnated (VPI)  Distribution Transformer
  • Dry Type Varnish Impregnated (VPI)  Distribution Transformer
Get Best Quote
Approx. Price: Rs 35,000 / PieceGet Latest Price

Product Details:

Make" KAY PEE "
Type Of CoolingAN / AF
No Load LossAs Per Costumer Required
StandardIS 11171 , IS 2026
KVAAs Per Costumer Requirement ( 10 KVA To 2500 KVA )
Temprature RiseAs Per Insulation Lavel
No load CurrentLess Then 3 Percentage of rated Current
Vector GroupAs Per Costumer Required
TappingAs Per Costumer Requirement( Generally +5% To -5%)
ImpedanceAs Per Costumer Demand
Full Load LossAs Per Costumer Required
Secondary Voltage0.433 KV Or As Per Costumer Requirement
Supply Frequency50 / 60 Hz
InstallationIndoor / Outdoor
Orientation Of HV And LVGeneral 180 Degree If Required 90 Degree
No Of PhaseThree
Nominal Voltage11 KV / 22 KV / 33 KV
EncloserYes / No
Class Of InsulationF Or H Or C

KAY PEE offers a complete range of power and distribution transformers designed to grant the reliability, durability, and efficiency required in utility, industrial, and commercial applications. KAY PEE 's VPI transformers are manufactured in accordance with the most demanding industry and international standards. Transformers can be used for indoor or outdoor applications and can be provided with off-load and on-load tap changers.

The transformer are manufactured in accordance with IS 2026/1977, IS 11171/1885, IEC 60076 or as per customer’s custom requirement.

The transformers will be suitable for outdoor or indoor installation with three phase, 50Hz, 11 kV system in which the neutral is effectively earthed and they should be suitable for service with fluctuations in supply voltage up to plus 5% to minus 5%.


Dry-type transformer: Transformer of which the magnetic circuit and windings are not immersed in an insulating liquid.


Encloser : Design of encloser is dependent upon the location and environmental condition in which transformer installed.


Totally enclosed dry-type transformer: Transformer in an un-pressurized enclosure cooled by the circulation of the internal air.


Enclosed dry-type transformer: Transformer in a ventilated enclosure cooled by the circulation of the external air.


Non-enclosed dry-type transformer: Transformer supplied without a protective enclosure cooled by natural or forced air ventilation.


Operation with Fan Cooling : When additional cooling by means of fans is provided, the nominal power rating with and without fans shall be subject to agreement between purchaser and supplier. The rating plate shall indicate both the power rating without fans and the maximum power rating with fan cooling


Humidity: The relative humidity of the surrounding air shall be less than 93 %. No drops of water shall be present on the surface of the coils.

Range : The standard ratings shall be 10, 16, 25, 63, 100, 160, 200, 250, 315, 400,500, 630, 800, 1000, 1250, 1500, 1600, 2000 and 2500 kVA for 11 kV distribution transformers


Vector Group : As per customer’s custom requirement.

Core : The core shall be stack / wound type of high grade cold rolled grain oriented annealed steel lamination having low loss and good grain properties, coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise.

Core Test : The preliminary core loss test will be conducted before passing to the assembly stage.

Winding : HV and LV windings shall be wound from Super Enamel covered /Double Paper covered, aluminum /copper conductor/ foil.

 

Insulation Level : For Dry Type Transformer Class of Insulation will be F , H , C


Tapings : For ratings higher than 250 kVA, tapping shall be provided if required by the purchaser on the higher voltage winding for variation of HV voltage within range of (+) 5.0 % to (-)15.0 % in steps of 2.5%.


BUSHINGS: for 11 kV, 17.5 kV class bushings and for 0.433 kV, 1.1 kV class bushings shall be used.


TESTING : We are conduct all routin test.

Request
Callback
Yes! I am Interested

Air Cooled Distribution Transformer

Air Cooled Distribution Transformer
  • Air Cooled Distribution Transformer
Get Best Quote
Approx. Price: Rs 35,000 / OnwardGet Latest Price

Product Details:

No Load LossAs Per Costumer Required
StandardIS 11171 , IS 2026
No Of PhaseThree
Secondary Voltage0.433 KV Or As Per Costumer Requirement
Type Of CoolingAN / AF
Class Of InsulationF Or H Or C
Temprature RiseAs Per Insulation Lavel
Vector GroupAs Per Costumer Required
Full Load LossesAs Per costumer Requirement
InstallationIndoor / Outdoor
OrientationGeneral 180 degree If Required 90 Degree
TappingAs Per Costumer Requirement( Generally +5% To -5%)
Nominal Voltage11 KV / 22 KV / 33 KV
Supply Frequency50 / 60 Hz
EncloserYes / No
No load CurrentLess Then 3 Percentage of rated Current
KVA capacityAs Per Costumer Requirement (10 KVA To 2500 KVA)
Brand" KAY PEE "

KAY PEE offers a complete range of power and distribution transformers designed to grant the reliability, durability, and efficiency required in utility, industrial, and commercial applications. KAY PEE 's Air Cooled transformers are manufactured in accordance with the most demanding industry and international standards. Transformers can be used for indoor or outdoor applications and can be provided with off-load and on-load tap changers.

The transformer are manufactured in accordance with IS 2026/1977, IS 11171/1885, IEC 60076 or as per customer’s custom requirement.

The transformers will be suitable for outdoor or indoor installation with three phase, 50Hz, 11 kV system in which the neutral is effectively earthed and they should be suitable for service with fluctuations in supply voltage up to plus 5% to minus 5%.


Dry-type transformer: Transformer of which the magnetic circuit and windings are not immersed in an insulating liquid.


Encloser : Design of encloser is dependent upon the location and environmental condition in which transformer installed.


Totally enclosed dry-type transformer: Transformer in an un-pressurized enclosure cooled by the circulation of the internal air.


Enclosed dry-type transformer: Transformer in a ventilated enclosure cooled by the circulation of the external air.


Non-enclosed dry-type transformer: Transformer supplied without a protective enclosure cooled by natural or forced air ventilation.


Operation with Fan Cooling : When additional cooling by means of fans is provided, the nominal power rating with and without fans shall be subject to agreement between purchaser and supplier. The rating plate shall indicate both the power rating without fans and the maximum power rating with fan cooling


Humidity: The relative humidity of the surrounding air shall be less than 93 %. No drops of water shall be present on the surface of the coils.

Range : The standard ratings shall be 10, 16, 25, 63, 100, 160, 200, 250, 315, 400,500, 630, 800, 1000, 1250, 1500, 1600, 2000 and 2500 kVA for 11 kV distribution transformers


Vector Group : As per customer’s custom requirement.

Core : The core shall be stack / wound type of high grade cold rolled grain oriented annealed steel lamination having low loss and good grain properties, coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise.

Core Test : The preliminary core loss test will be conducted before passing to the assembly stage.

Winding : HV and LV windings shall be wound from Super Enamel covered /Double Paper covered, aluminum /copper conductor/ foil.

 

Insulation Level : For Dry Type Transformer Class of Insulation will be F , H , C


Tapings : For ratings higher than 250 kVA, tapping shall be provided if required by the purchaser on the higher voltage winding for variation of HV voltage within range of (+) 5.0 % to (-)15.0 % in steps of 2.5%.


BUSHINGS: for 11 kV, 17.5 kV class bushings and for 0.433 kV, 1.1 kV class bushings shall be used.


TESTING : We are conduct all routin test.