Distribution Transformer Is An Electrical Isolation Transformer Which Convert Higher Voltage Electricity To Lower Voltage Levels Acceptable For Use In Homes & Industries. A Distribution Transformer's Function Is Straight Forward : To Step Down The Voltage & Provide Isolation Between Primary & Secondary. Electrical Energy Is Passed Through Distribution Transformers To Reduce High Distribution Voltage Levels Down To End Use Levels. Nearly All Energy Passes Through At Least One Distribution Transformer Before Being Consumed By An End Use Appliance , Motor Or Other Piece Of Equipment. Distribution Transformers Are Found In All Sectors Of The Economy : Residential , Commercial & Industrial.
Distribution Transformers Are Generally Categorized In Several Ways :
₹ 3500000 / unit Get Latest Price
| Capacity | 2000 kVA |
| Winding Material | Copper |
| Voltage Class | 11 kV / 0.433 kV |
| Cooling Type | Oil Natural Air Natural (ONAN) |
| Applicable Standard | IS 1180 |
| Tapping Type | Off-Circuit Tap Changer (OCTC) |
| Energy Efficiency | Level 1 (IS 1180) |
| Core Type | CRGO Stack Core |
| Insulating Fluid | Mineral Oil |
| Accessories | Winding Temperature Indicator (WTI), Oil Temperature Indicator (OTI), HV/LV Cable Box, Buchholz Relay, Silica Gel Breather |
| Kva Capacity | 2000 Kva |
| HV Voltage | 11000v |
| IV Voltage | 433v |
| Type of Installation | Indoor |
| HV Current Capacity | 104.9758556 |
| IV Current Capacity | 2666.666667 |
| Frequency | 50/60 Hz |
| Vector Group of Product | DYN11 |
| % Impidance | 6.25 (as per requirement) |
| HV Variation | +/- 5% |
| Temperature Oil | 40 degree celsius |
| Temperature Winding | 45 degree celsius |
Minimum order quantity: 1 unit
₹ 2180000 / Piece Get Latest Price
| Power | 1000 Kva |
| KVA capicity | 1000 Kva |
| Energy Lable | Buro of indian standard Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Cooling | ONAN |
| Types of Tapechainger | OCTC |
| Tapping Range | +/- 5% |
| 50% Losses | 2790 W |
| 100% Losses | 7700 W |
| Impidence | 5% Talerance +/- 10% (As Per Requirement ) |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
Minimum order quantity: 1 Piece
₹ 1957000 / Piece Get Latest Price
| Power Rating | 800 KVA |
| Power | 800Kva |
| KVA capicity | 800 Kva |
| Energy Lable | Buro of indian standard Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Cooling | ONAN |
| Types of Tapechainger | OCTC |
| Tapping Range | +/- 5% |
| 50% Losses | 2287 W |
| 100% Losses | 6404 W |
| Impidence | 5% Talerance +/- 10% (As Per Requirement ) |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
Minimum order quantity: 1 Piece
₹ 4047000 / Piece Get Latest Price
| Power | 2500Kva |
| KVA capicity | 2500 Kva |
| Energy Lable | Buro of indian standard Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Cooling | ONAN |
| Types of Tapechainger | OCTC |
| Tapping Range | +/- 5% |
| 50% Losses | 6150 W |
| 100% Losses | 18500 W |
| Impidence | 5% Talerance +/- 10% (As Per Requirement ) |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
Minimum order quantity: 1 Piece
₹ 3902500 / Piece Get Latest Price
| Power Rating | 5000 KVA |
| KVA capicity | 5000 KVA |
| Energy Lable | As Per Is : 2026 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Cooling | ONAN |
| Types of Tapechainger | OCTC |
| Taping Range in + | 5 % |
| Taping Range in - | 5 % |
| No Load Losses | 4000 W |
| Load Losses | 46000 W |
| Full Load Losses | 50000 W |
| Impidence | 7 % |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
Minimum order quantity: 1 Piece
What is IS‑2026
Here are the usual components and features of oil‑cooled transformers meeting IS 2026:
|
||||||||||||||||||||||||||||
₹ 1800000 / Piece Get Latest Price
| Power Rating | 1MVA |
| Number of Phase | 3-Phase |
| Cooling Type | ONAN |
| Winding Material | Copper |
| Voltage Ratio | 11kV/433V |
| Short circuit impedance | 5.00 % |
| Manufactured By | Kay Pee |
| Reference Standard | IS 1180 |
| Standards | IS-1180 |
| Brand | Kay Pee |
| Energy Efficiency Level | 1 |
| Insulation Class | A |
| AMC Available | Yes |
| Onsite Support Available | Yes |
| Winding Turns | Step-Down |
| Country of Origin | Made in India |
Minimum order quantity: 1 Piece
₹ 3092000 / Piece Get Latest Price
| Power | 1600 Kva |
| KVA capicity | 1600 Kva |
| Energy Lable | Buro of indian standard Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Cooling | ONAN |
| Types of Tapechainger | OCTC |
| Tapping Range | +/- 5% |
| 50% Losses | 4200 W |
| 100% Losses | 11800 W |
| Impidence | 6.5% Talerance +/- 10% (As Per Requirement ) |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
Minimum order quantity: 1 Piece
₹ 2445000 / Piece Get Latest Price
| Power | 1250 Kva |
| KVA capicity | 1250 Kva |
| Energy Lable | Buro of indian standard Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Cooling | ONAN |
| Types of Tapechainger | OCTC |
| Tapping Range | +/_ 5 % |
| 50% Losses | 3300 W |
| 100% Losses | 9200 W |
| Impidence | 5% Talerance +/- 10% (As Per Requirement ) |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
Minimum order quantity: 1 Piece
₹ 1426000 / Piece Get Latest Price
| Power | 400 kva |
| KVA capicity | 400 KVA |
| Energy Lable | Buro of indian standard Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Cooling | ONAN |
| Types of Tapechainger | OCTC |
| Tapping Range | =/- 5% |
| 50% Losses | 1255 W |
| 100% Losses | 3450 W |
| Impidence | 4.5 % Talerance +/- 10% (As Per Requirement ) |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
Minimum order quantity: 1 Piece
₹ 1592000 / Piece Get Latest Price
| Power | 630 kva |
| Cooling Type | Oil Cooled |
| Phase | 3 Phase |
| Insulation Class | A |
| AMC Available | Yes |
| Onsite Support Available | Yes |
Minimum order quantity: 1 Piece
₹ 857000 / Piece Get Latest Price
| Power Rating | 250 KVA |
| Capacity | 250 kVA |
| Power | 250 KVA |
| Winding Material | Copper |
| Vector Group | DYN11 (As Per Requirement ) |
| KVA capicity | 250 KVA |
| Energy Lable | Buro of indian standard Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Cooling | ONAN |
| Types of Tapechainger | OCTC |
| Tapping Range | +/- 5% |
| 50% Losses | 980 W |
| 100% Losses | 2930 W |
| Impidence | 4.5 % Talerance +/- 10% (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
Minimum order quantity: 1 Piece
Cooling Types: Oil-cooled (ONAN/ONAF)
Mounting:Either pole-mounted or ground-mounted depending on design and space constraints.
₹ 335000 / Piece Get Latest Price
| Phase | Three Phase |
| Input Voltage | 11 KV & 22 KV & 33 KV (As Per Customer's Demand) |
| Brand | KAY PEE |
| Output Voltage | 0.433 KV (As Per Customer's Demand) |
| Frequency | 50 HZ |
| Winding Material | E. C. Grade D. P. C. Copper Wire & Strips |
| Class Of Insulation | A |
| Orientation Of HV and LV | 180 Degree (As Per Customer's Demand) |
| Temprature Rise Oil and Winding | 40 DegreeC (In Oil) & 45 DegreeC (In Winding) |
| Taping | As Per Customer's Demand |
| Impedance | As Per BIS |
| No load Current | Less Than 2 % Of Full Load Current |
| No Load Losses | As Per Customer's Demand |
| Full Load Losses | As Per BIS Level |
| Load Losses At Half Load | As Per BIS Level |
| Rated Capacity | As Per Customer's Demand |
| No Of Phase | Three |
| Installaton | Indoor / Outdoor |
| Vector Groupe | As Per Customer's Demand |
| Type Of Cooling | Oil Cooled |
₹ 335000 / Piece Get Latest Price
| Vector Group | As Per Costumer Requirement |
| Rated KVA | KVA Capacity As Per requirement (250 KVA To 2500 KVA) |
| Taping | As Per Costumer Requirement( Generally +5% To -5%) |
| Impedance | As Per BIS |
| No Load Losses | As Per Costumer Requirement |
| Full Load Losses | As per BIS Lavel |
| Load Losses At Half Load | As Per BIS Lavel |
| No load Current | Less Then 3 Percentage |
| Standard | IS 1180 |
| No Of Phase | Three |
| Nominal Voltage | 11 KV / 22 KV / 33 KV |
| Secondary Voltage | As Per Costumer Requirement (Generally 433 Voltage) |
| Instalaton | Indoor / Outdoor |
| Type Of Cooling | Oil Cooled |
| Orientation Of HV And LV | General 180 Degree And If Required 90 Degree |
| Temprature rise Oil And Winding | 50/55 degree |
The transformers will be suitable for outdoor installation with three phase, 50Hz, 11 kV system in which the neutral is effectively earthed and theyshould be suitable for service with fluctuations in supply voltage up to plus 12.5% to minus 12.5%.
Range :The standard ratings shall be 250, 315, 400, 500, 630, 800, 1000, 1250, 1500, 1600, 2000 and 2500 KVA for 11 kV distribution transformers.
Vector Group : As percustomer’s custom requirement.
Core : The core shall be stack / wound type of high grade cold rolled grain oriented annealed steel lamination having low loss and good grain properties, coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise.
Core Test : The preliminary core loss test will be conducted before passing to the assembly stage.
Winding : HV and LV windings shall be wound from Super Enamel covered /Double Paper covered, aluminum /copper conductor/ foil.
Tapings : For ratings higher than 250 kVA, tapping shall be provided if required by the purchaser on the higher voltage winding for variation of HV voltage within range of (+) 5.0 % to (-)15.0 % in steps of 2.5%.
OIL : The insulating oil shall comply with the requirements of IS 335 or BS 148 Oil shall be filtered and tested for break down voltage (BDV) and moisture content before filling. The oil shall be filled under vacuum.
Tank :The transformer tank is of robust construction rectangular in shape and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for top and bottom and 4 mm side plate.
Conservator : The capacity of a conservator tank is designed keeping in Observation the total quantity of oil and its contraction and expansion due to temperature variations The total volume of conservator shall be such as to contain10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator.
BUSHINGS: for 11 kV, 17.5 kV class bushings and for 0.433 kV, 1.1 kV class bushings shall be used.
TESTING : We are conduct all routin test.
₹ 335000 / Piece Get Latest Price
| Rated KVA | As costumer requirement(250 KVA To 2500 KVA) |
| Taping | As Per Costumer Requirement( Generally +5% To -5%) |
| Impedance | As Per BIS |
| No Load Losses | As Per Costumer Requirement |
| Full Load Losses | As per BIS Lavel |
| Load Losses At Half Load | As Per BIS Lavel |
| No Of Phase | Three |
| Nominal Voltage | 11 KV / 22 KV / 33 KV |
| Secondary Voltage | As Per Costumer Requirement (Generally 433 Voltage) |
| Installaton | Indoor / Outdoor |
| Type Of Cooling | Oil Cooled |
| Vector Group | As Per Costumer Requirement |
| Orientation Of HV And LV | General 180 Degree And If Required 90 Degree |
| Temprature rise Oil And Winding | 50 / 55 degree |
The transformers will be suitable for outdoor installation with three phase, 50Hz, 11 kV system in which the neutral is effectively earthed and theyshould be suitable for service with fluctuations in supply voltage up to plus 12.5% to minus 12.5%.
Range : The standard ratings shall be 250, 315, 400, 500, 630, 800, 1000, 1250, 1500, 1600, 2000 and 2500 KVA for 11 kV distribution transformers.
Vector Group : As per customer’s custom requirement.
Core : The core shall be stack / wound type of high grade cold rolled grain oriented annealed steel lamination having low loss and good grain properties, coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise.
Core Test : The preliminary core loss test will be conducted before passing to the assembly stage.
Winding : HV and LV windings shall be wound from Super Enamel covered /Double Paper covered, aluminum /copper conductor/ foil.
Tapings : For ratings higher than 250 kVA, tapping shall be provided if required by the purchaser on the higher voltage winding for variation of HV voltage within range of (+) 5.0 % to (-)15.0 % in steps of 2.5%.
OIL : The insulating oil shall comply with the requirements of IS 335 or BS 148 Oil shall be filtered and tested for break down voltage (BDV) and moisture content before filling. The oil shall be filled under vacuum.
Tank :The transformer tank is of robust construction rectangular in shape and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for top and bottom and 4 mm side plate.
Conservator : The capacity of a conservator tank is designed keeping in Observation the total quantity of oil and its contraction and expansion due to temperature variations The total volume of conservator shall be such as to contain10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator.
BUSHINGS: for 11 kV, 17.5 kV class bushings and for 0.433 kV, 1.1 kV class bushings shall be used.
TESTING : We are conduct all routin test.
₹ 335000 / Unit Get Latest Price
| Rated KVA | As costumer requirement(250 KVA To 2500 KVA) |
| No Of Phase | Three |
| Supply Frequency | 50 / 60 Hz |
| Nominal Voltage | 11 KV / 22 KV / 33 KV |
| Secondary Voltage | As Per Costumer Requirement (Generally 433 Voltage) |
| Installation | indoor / Outdoor |
| Type Of Cooling | Oil Cooled |
| Phase Group | As Per vector group |
| Orientation Of HV And LV | General 180 Degree And If Required 90 Degree |
| Temprature Rise Oil And Winding | 50 / 55 Degree |
| Tapping | As Per Costumer Requirement( Generally +5% To -5%) |
| Impedance | As Per BIS |
| No Load Losses | As Per Costumer Requirement |
| No Load Current | Less Then 3 Percentage |
| Full Load Losses | As per BIS Lavel |
| Load Loss At Half Load | As Per BIS Lavel |
The transformers will be suitable for outdoor installation with three phase, 50Hz, 11 kV system in which the neutral is effectively earthed and theyshould be suitable for service with fluctuations in supply voltage up to plus 12.5% to minus 12.5%.
Range : The standard ratings shall be 250, 315, 400, 500, 630, 800, 1000, 1250, 1500, 1600, 2000 and 2500 KVA for 11 kV distribution transformers.
Vector Group : As per customer’s custom requirement.
Core : The core shall be stack / wound type of high grade cold rolled grain oriented annealed steel lamination having low loss and good grain properties, coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise.
Core Test : The preliminary core loss test will be conducted before passing to the assembly stage.
Winding : HV and LV windings shall be wound from Super Enamel covered /Double Paper covered, aluminum /copper conductor/ foil.
Tapings : For ratings higher than 250 kVA, tapping shall be provided if required by the purchaser on the higher voltage winding for variation of HV voltage within range of (+) 5.0 % to (-)15.0 % in steps of 2.5%.
OIL : The insulating oil shall comply with the requirements of IS 335 or BS 148 Oil shall be filtered and tested for break down voltage (BDV) and moisture content before filling. The oil shall be filled under vacuum.
Tank :The transformer tank is of robust construction rectangular in shape and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for top and bottom and 4 mm side plate.
Conservator : The capacity of a conservator tank is designed keeping in Observation the total quantity of oil and its contraction and expansion due to temperature variations The total volume of conservator shall be such as to contain10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator.
BUSHINGS: for 11 kV, 17.5 kV class bushings and for 0.433 kV, 1.1 kV class bushings shall be used.
TESTING : We are conduct all routin test.
₹ 335000 / Piece Get Latest Price
| Phase | Three Phase |
| Rated KVA | As Per costumer requirement(250 KVA To 2500 KVA) |
| Temprature rise Oil and Winding | 50 / 55 degree |
| Taping | As Per Costumer Requirement( Generally +5% To -5%) |
| Impedance | As Per BIS |
| No Load losses | As Per Costumer Requirement |
| No load Current | Less Then 3 Percentage of Full Load current |
| Fill Load Losses | As Per BIS Lavel |
| Load Losses At Half Load | As Per BIS Lavel |
| No Of Phase | Three |
| Nominal Voltage | 11 KV / 22 KV / 33 KV |
| Secondary Voltage | As Per Costumer Requirement (Generally 433 Voltage) |
| supply Frequency | 50 / 60 Hz |
| Installation | indoor / Outdoor |
| Type Of Cooling | Oil Cooled |
| phase Group | As per Vector Group |
| Orientation Of HV And LV | General 180 Degree And If Required 90 Degree |
The transformers will be suitable for outdoor installation with three phase, 50Hz, 11 kV system in which the neutral is effectively earthed and theyshould be suitable for service with fluctuations in supply voltage up to plus 12.5% to minus 12.5%.
Range : The standard ratings shall be 250, 315, 400, 500, 630, 800, 1000, 1250, 1500, 1600, 2000 and 2500 KVA for 11 kV distribution transformers.
Vector Group : As per customer’s custom requirement.
Core : The core shall be stack / wound type of high grade cold rolled grain oriented annealed steel lamination having low loss and good grain properties, coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise.
Core Test : The preliminary core loss test will be conducted before passing to the assembly stage.
Winding : HV and LV windings shall be wound from Super Enamel covered /Double Paper covered, aluminum /copper conductor/ foil.
Tapings : For ratings higher than 250 kVA, tapping shall be provided if required by the purchaser on the higher voltage winding for variation of HV voltage within range of (+) 5.0 % to (-)15.0 % in steps of 2.5%.
OIL : The insulating oil shall comply with the requirements of IS 335 or BS 148 Oil shall be filtered and tested for break down voltage (BDV) and moisture content before filling. The oil shall be filled under vacuum.
Tank :The transformer tank is of robust construction rectangular in shape and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for top and bottom and 4 mm side plate.
Conservator : The capacity of a conservator tank is designed keeping in Observation the total quantity of oil and its contraction and expansion due to temperature variations The total volume of conservator shall be such as to contain10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator.
BUSHINGS: for 11 kV, 17.5 kV class bushings and for 0.433 kV, 1.1 kV class bushings shall be used.
TESTING : We are conduct all routin test.
₹ 1352000 / Piece Get Latest Price
| Power | 250 kVA |
| KVA Capicity | 250 KVA |
| Energy Lable | As Per Energy Efficient Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Tapechainger | OlTC |
| Tapping Range in + | 10 % |
| Tapping Range in - | 10 % |
| 50% Losses | 980 W |
| 100% Losses | 2930 W |
| Impidence | 4.5 % |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
| Types of Cooling | ONAN |
Minimum order quantity: 1 Piece
An Oil-Cooled Distribution Transformer with OLTC (On-Load Tap Changer) is a critical component in power distribution systems. Here's a clear and structured description of this equipment:
Oil-Cooled Distribution Transformer with OLTC 1. Basic FunctionA distribution transformer steps down high-voltage electricity (from transmission lines) to a lower voltage suitable for local distribution to homes, businesses, or industries.
2. Cooling Method: Oil-CooledThe transformer uses mineral oil or synthetic insulating oil for:
Cooling: Dissipates heat from the windings and core.
Insulation: Provides electrical insulation between internal components.
It usually has radiators, cooling fins, or even fans to aid in heat dissipation.
OLTC adjusts the transformer’s output voltage without interrupting the load.
It compensates for voltage variations in the supply network due to:
Load changes
Line losses
Network voltage fluctuations
OLTC changes the number of turns in the transformer winding.
This is done by switching taps on the high-voltage winding while the transformer is in operation.
Uses arcing contacts, resistors, or reactors to manage voltage steps safely.
Controlled either manually, remotely, or via automatic voltage control relays (AVRs).
| Component | Description |
|---|---|
| Core | Laminated steel core for magnetic flux |
| Windings | Copper or aluminum conductors for HV/LV sides |
| Transformer Oil | Cools and insulates the internal parts |
| Tank & Radiators | Steel tank filled with oil and cooling radiators/fins |
| OLTC Unit | Tap changing switch, motor drive, and control panel |
| Conservator Tank | Holds reserve oil and manages oil expansion |
| Breather (Silica Gel) | Removes moisture from the air entering the conservator |
| Buchholz Relay | Gas-accumulation protection (in larger transformers) |
| Temperature Gauges & Oil Level Indicators | Monitoring instruments |
Utility power distribution substations
Industrial plants
Large commercial buildings
Renewable energy (solar/wind farms)
₹ 2008000 / Piece Get Latest Price
| Power | 630 KVA |
| KVA Capicity | 630 KVA |
| Energy Lable | As Per Energy Efficient Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Tapechainger | OlTC |
| Tapping Range in + | 10% |
| Tapping Range in - | 10% |
| 50% Losses | 1860 W |
| 100% Losses | 5300 W |
| Impidence | 4.5 % |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
| Types of Cooling | ONAN |
Minimum order quantity: 1 Piece
An Oil-Cooled Distribution Transformer with OLTC (On-Load Tap Changer) is a critical component in power distribution systems. Here's a clear and structured description of this equipment:
Oil-Cooled Distribution Transformer with OLTC 1. Basic FunctionA distribution transformer steps down high-voltage electricity (from transmission lines) to a lower voltage suitable for local distribution to homes, businesses, or industries.
2. Cooling Method: Oil-CooledThe transformer uses mineral oil or synthetic insulating oil for:
Cooling: Dissipates heat from the windings and core.
Insulation: Provides electrical insulation between internal components.
It usually has radiators, cooling fins, or even fans to aid in heat dissipation.
OLTC adjusts the transformer’s output voltage without interrupting the load.
It compensates for voltage variations in the supply network due to:
Load changes
Line losses
Network voltage fluctuations
OLTC changes the number of turns in the transformer winding.
This is done by switching taps on the high-voltage winding while the transformer is in operation.
Uses arcing contacts, resistors, or reactors to manage voltage steps safely.
Controlled either manually, remotely, or via automatic voltage control relays (AVRs).
| Component | Description |
|---|---|
| Core | Laminated steel core for magnetic flux |
| Windings | Copper or aluminum conductors for HV/LV sides |
| Transformer Oil | Cools and insulates the internal parts |
| Tank & Radiators | Steel tank filled with oil and cooling radiators/fins |
| OLTC Unit | Tap changing switch, motor drive, and control panel |
| Conservator Tank | Holds reserve oil and manages oil expansion |
| Breather (Silica Gel) | Removes moisture from the air entering the conservator |
| Buchholz Relay | Gas-accumulation protection (in larger transformers) |
| Temperature Gauges & Oil Level Indicators | Monitoring instruments |
Utility power distribution substations
Industrial plants
Large commercial buildings
Renewable energy (solar/wind farms)
₹ 1929000 / Piece Get Latest Price
| Power | 500 kVA |
| KVA Capicity | 500 KVA |
| Energy Lable | As Per Energy Efficient Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Tapechainger | OlTC |
| Tapping Range in + | 10% |
| Tapping Range in - | 10% |
| 50% Losses | 1510 W |
| 100% Losses | 4300 W |
| Impidence | 4.5 % |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
| Types of Cooling | ONAN |
Minimum order quantity: 1 Piece
An Oil-Cooled Distribution Transformer with OLTC (On-Load Tap Changer) is a critical component in power distribution systems. Here's a clear and structured description of this equipment:
Oil-Cooled Distribution Transformer with OLTC 1. Basic FunctionA distribution transformer steps down high-voltage electricity (from transmission lines) to a lower voltage suitable for local distribution to homes, businesses, or industries.
2. Cooling Method: Oil-CooledThe transformer uses mineral oil or synthetic insulating oil for:
Cooling: Dissipates heat from the windings and core.
Insulation: Provides electrical insulation between internal components.
It usually has radiators, cooling fins, or even fans to aid in heat dissipation.
OLTC adjusts the transformer’s output voltage without interrupting the load.
It compensates for voltage variations in the supply network due to:
Load changes
Line losses
Network voltage fluctuations
OLTC changes the number of turns in the transformer winding.
This is done by switching taps on the high-voltage winding while the transformer is in operation.
Uses arcing contacts, resistors, or reactors to manage voltage steps safely.
Controlled either manually, remotely, or via automatic voltage control relays (AVRs).
| Component | Description |
|---|---|
| Core | Laminated steel core for magnetic flux |
| Windings | Copper or aluminum conductors for HV/LV sides |
| Transformer Oil | Cools and insulates the internal parts |
| Tank & Radiators | Steel tank filled with oil and cooling radiators/fins |
| OLTC Unit | Tap changing switch, motor drive, and control panel |
| Conservator Tank | Holds reserve oil and manages oil expansion |
| Breather (Silica Gel) | Removes moisture from the air entering the conservator |
| Buchholz Relay | Gas-accumulation protection (in larger transformers) |
| Temperature Gauges & Oil Level Indicators | Monitoring instruments |
Utility power distribution substations
Industrial plants
Large commercial buildings
Renewable energy (solar/wind farms)
₹ 1820000 / Piece Get Latest Price
| Power | 400 kVA |
| KVA Capicity | 400 KVA |
| Energy Lable | As Per Energy Efficient Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Tapechainger | OlTC |
| Tapping Range in + | 10% |
| Tapping Range in - | 10% |
| 50% Losses | 1225 w |
| 100% Losses | 3450 w |
| Impidence | 4.5 % |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
| Types of Cooling | ONAN |
Minimum order quantity: 1 Piece
An Oil-Cooled Distribution Transformer with OLTC (On-Load Tap Changer) is a critical component in power distribution systems. Here's a clear and structured description of this equipment:
Oil-Cooled Distribution Transformer with OLTC 1. Basic FunctionA distribution transformer steps down high-voltage electricity (from transmission lines) to a lower voltage suitable for local distribution to homes, businesses, or industries.
2. Cooling Method: Oil-CooledThe transformer uses mineral oil or synthetic insulating oil for:
Cooling: Dissipates heat from the windings and core.
Insulation: Provides electrical insulation between internal components.
It usually has radiators, cooling fins, or even fans to aid in heat dissipation.
OLTC adjusts the transformer’s output voltage without interrupting the load.
It compensates for voltage variations in the supply network due to:
Load changes
Line losses
Network voltage fluctuations
OLTC changes the number of turns in the transformer winding.
This is done by switching taps on the high-voltage winding while the transformer is in operation.
Uses arcing contacts, resistors, or reactors to manage voltage steps safely.
Controlled either manually, remotely, or via automatic voltage control relays (AVRs).
| Component | Description |
|---|---|
| Core | Laminated steel core for magnetic flux |
| Windings | Copper or aluminum conductors for HV/LV sides |
| Transformer Oil | Cools and insulates the internal parts |
| Tank & Radiators | Steel tank filled with oil and cooling radiators/fins |
| OLTC Unit | Tap changing switch, motor drive, and control panel |
| Conservator Tank | Holds reserve oil and manages oil expansion |
| Breather (Silica Gel) | Removes moisture from the air entering the conservator |
| Buchholz Relay | Gas-accumulation protection (in larger transformers) |
| Temperature Gauges & Oil Level Indicators | Monitoring instruments |
Utility power distribution substations
Industrial plants
Large commercial buildings
Renewable energy (solar/wind farms)
₹ 1494000 / Piece Get Latest Price
| Power | 500 kva |
| KVA capicity | 500 kva |
| Energy Lable | Buro of indian standard Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Tapechainger | OCTC |
| Tapping Range | +/- 5% |
| 50% Losses | 1510 W |
| 100% Losses | 4300 W |
| Impidence | 4.5 % Talerance +/- 10% (As Per Requirement ) |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
| Types of Cooling | ONAN |
Minimum order quantity: 1 Piece
₹ 4189000 / Piece Get Latest Price
| Power | 2500 KVA |
| Country of Origin | Made in India |
| KVA Capicity | 2500 KVA |
| Energy Lable | As Per Energy Efficient Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Tapechainger | OlTC |
| Tapping Range in + | 10 % |
| Tapping Range in - | 10 % |
| 50% Losses | 6150 % |
| 100% Losses | 18500 % |
| Impidence | 6.25 % |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
| Types of Cooling | ONAN |
Minimum order quantity: 1 Piece
An Oil-Cooled Distribution Transformer with OLTC (On-Load Tap Changer) is a critical component in power distribution systems. Here's a clear and structured description of this equipment:
Oil-Cooled Distribution Transformer with OLTC 1. Basic FunctionA distribution transformer steps down high-voltage electricity (from transmission lines) to a lower voltage suitable for local distribution to homes, businesses, or industries.
2. Cooling Method: Oil-CooledThe transformer uses mineral oil or synthetic insulating oil for:
Cooling: Dissipates heat from the windings and core.
Insulation: Provides electrical insulation between internal components.
It usually has radiators, cooling fins, or even fans to aid in heat dissipation.
OLTC adjusts the transformer’s output voltage without interrupting the load.
It compensates for voltage variations in the supply network due to:
Load changes
Line losses
Network voltage fluctuations
OLTC changes the number of turns in the transformer winding.
This is done by switching taps on the high-voltage winding while the transformer is in operation.
Uses arcing contacts, resistors, or reactors to manage voltage steps safely.
Controlled either manually, remotely, or via automatic voltage control relays (AVRs).
| Component | Description |
|---|---|
| Core | Laminated steel core for magnetic flux |
| Windings | Copper or aluminum conductors for HV/LV sides |
| Transformer Oil | Cools and insulates the internal parts |
| Tank & Radiators | Steel tank filled with oil and cooling radiators/fins |
| OLTC Unit | Tap changing switch, motor drive, and control panel |
| Conservator Tank | Holds reserve oil and manages oil expansion |
| Breather (Silica Gel) | Removes moisture from the air entering the conservator |
| Buchholz Relay | Gas-accumulation protection (in larger transformers) |
| Temperature Gauges & Oil Level Indicators | Monitoring instruments |
Utility power distribution substations
Industrial plants
Large commercial buildings
Renewable energy (solar/wind farms)
₹ 3633000 / Piece Get Latest Price
| Power | 1600 kVA |
| KVA Capicity | 1600 KVA |
| Energy Lable | As Per Energy Efficient Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Tapechainger | OlTC |
| Tapping Range in + | 10 % |
| Tapping Range in - | 10 % |
| 50% Losses | 4200 W |
| 100% Losses | 11800 W |
| Impidence | 6.25 % |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
| Types of Cooling | ONAN |
Minimum order quantity: 1 Piece
An Oil-Cooled Distribution Transformer with OLTC (On-Load Tap Changer) is a critical component in power distribution systems. Here's a clear and structured description of this equipment:
Oil-Cooled Distribution Transformer with OLTC 1. Basic FunctionA distribution transformer steps down high-voltage electricity (from transmission lines) to a lower voltage suitable for local distribution to homes, businesses, or industries.
2. Cooling Method: Oil-CooledThe transformer uses mineral oil or synthetic insulating oil for:
Cooling: Dissipates heat from the windings and core.
Insulation: Provides electrical insulation between internal components.
It usually has radiators, cooling fins, or even fans to aid in heat dissipation.
OLTC adjusts the transformer’s output voltage without interrupting the load.
It compensates for voltage variations in the supply network due to:
Load changes
Line losses
Network voltage fluctuations
OLTC changes the number of turns in the transformer winding.
This is done by switching taps on the high-voltage winding while the transformer is in operation.
Uses arcing contacts, resistors, or reactors to manage voltage steps safely.
Controlled either manually, remotely, or via automatic voltage control relays (AVRs).
| Component | Description |
|---|---|
| Core | Laminated steel core for magnetic flux |
| Windings | Copper or aluminum conductors for HV/LV sides |
| Transformer Oil | Cools and insulates the internal parts |
| Tank & Radiators | Steel tank filled with oil and cooling radiators/fins |
| OLTC Unit | Tap changing switch, motor drive, and control panel |
| Conservator Tank | Holds reserve oil and manages oil expansion |
| Breather (Silica Gel) | Removes moisture from the air entering the conservator |
| Buchholz Relay | Gas-accumulation protection (in larger transformers) |
| Temperature Gauges & Oil Level Indicators | Monitoring instruments |
Utility power distribution substations
Industrial plants
Large commercial buildings
Renewable energy (solar/wind farms)
₹ 3823000 / Piece Get Latest Price
| Power | 2000 kVA |
| KVA Capicity | 2000 KVA |
| Energy Lable | As Per Energy Efficient Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Tapechainger | OlTC |
| Tapping Range in + | 10 % |
| Tapping Range in - | 10 % |
| 50% Losses | 5050 W |
| 100% Losses | 15000 W |
| Impidence | 6.25 % |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
| Types of Cooling | ONAN |
Minimum order quantity: 1 Piece
An Oil-Cooled Distribution Transformer with OLTC (On-Load Tap Changer) is a critical component in power distribution systems. Here's a clear and structured description of this equipment:
Oil-Cooled Distribution Transformer with OLTC 1. Basic FunctionA distribution transformer steps down high-voltage electricity (from transmission lines) to a lower voltage suitable for local distribution to homes, businesses, or industries.
2. Cooling Method: Oil-CooledThe transformer uses mineral oil or synthetic insulating oil for:
Cooling: Dissipates heat from the windings and core.
Insulation: Provides electrical insulation between internal components.
It usually has radiators, cooling fins, or even fans to aid in heat dissipation.
OLTC adjusts the transformer’s output voltage without interrupting the load.
It compensates for voltage variations in the supply network due to:
Load changes
Line losses
Network voltage fluctuations
OLTC changes the number of turns in the transformer winding.
This is done by switching taps on the high-voltage winding while the transformer is in operation.
Uses arcing contacts, resistors, or reactors to manage voltage steps safely.
Controlled either manually, remotely, or via automatic voltage control relays (AVRs).
| Component | Description |
|---|---|
| Core | Laminated steel core for magnetic flux |
| Windings | Copper or aluminum conductors for HV/LV sides |
| Transformer Oil | Cools and insulates the internal parts |
| Tank & Radiators | Steel tank filled with oil and cooling radiators/fins |
| OLTC Unit | Tap changing switch, motor drive, and control panel |
| Conservator Tank | Holds reserve oil and manages oil expansion |
| Breather (Silica Gel) | Removes moisture from the air entering the conservator |
| Buchholz Relay | Gas-accumulation protection (in larger transformers) |
| Temperature Gauges & Oil Level Indicators | Monitoring instruments |
Utility power distribution substations
Industrial plants
Large commercial buildings
Renewable energy (solar/wind farms)
₹ 1666000 / Piece Get Latest Price
| Power | 315 kVA |
| KVA Capicity | 315 KVA |
| Energy Lable | As Per Energy Efficient Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Tapechainger | OlTC |
| Tapping Range in + | 10% |
| Tapping Range in - | 10% |
| 50% Losses | 1025 W |
| 100% Losses | 3100 W |
| Impidence | 4.5 % |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
| Types of Cooling | ONAN |
Minimum order quantity: 1 Piece
An Oil-Cooled Distribution Transformer with OLTC (On-Load Tap Changer) is a critical component in power distribution systems. Here's a clear and structured description of this equipment:
Oil-Cooled Distribution Transformer with OLTC 1. Basic FunctionA distribution transformer steps down high-voltage electricity (from transmission lines) to a lower voltage suitable for local distribution to homes, businesses, or industries.
2. Cooling Method: Oil-CooledThe transformer uses mineral oil or synthetic insulating oil for:
Cooling: Dissipates heat from the windings and core.
Insulation: Provides electrical insulation between internal components.
It usually has radiators, cooling fins, or even fans to aid in heat dissipation.
OLTC adjusts the transformer’s output voltage without interrupting the load.
It compensates for voltage variations in the supply network due to:
Load changes
Line losses
Network voltage fluctuations
OLTC changes the number of turns in the transformer winding.
This is done by switching taps on the high-voltage winding while the transformer is in operation.
Uses arcing contacts, resistors, or reactors to manage voltage steps safely.
Controlled either manually, remotely, or via automatic voltage control relays (AVRs).
| Component | Description |
|---|---|
| Core | Laminated steel core for magnetic flux |
| Windings | Copper or aluminum conductors for HV/LV sides |
| Transformer Oil | Cools and insulates the internal parts |
| Tank & Radiators | Steel tank filled with oil and cooling radiators/fins |
| OLTC Unit | Tap changing switch, motor drive, and control panel |
| Conservator Tank | Holds reserve oil and manages oil expansion |
| Breather (Silica Gel) | Removes moisture from the air entering the conservator |
| Buchholz Relay | Gas-accumulation protection (in larger transformers) |
| Temperature Gauges & Oil Level Indicators | Monitoring instruments |
Utility power distribution substations
Industrial plants
Large commercial buildings
Renewable energy (solar/wind farms)
₹ 2940000 / Piece Get Latest Price
| Power | 1250 KVA |
| KVA Capicity | 1250 KVA |
| Energy Lable | As Per Energy Efficient Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Tapechainger | OlTC |
| Tapping Range in + | 10 % |
| Tapping Range in - | 10 % |
| 50% Losses | 3300 W |
| 100% Losses | 9200 W |
| Impidence | 5 % |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
| Types of Cooling | ONAN |
Minimum order quantity: 1 Piece
An Oil-Cooled Distribution Transformer with OLTC (On-Load Tap Changer) is a critical component in power distribution systems. Here's a clear and structured description of this equipment:
Oil-Cooled Distribution Transformer with OLTC 1. Basic FunctionA distribution transformer steps down high-voltage electricity (from transmission lines) to a lower voltage suitable for local distribution to homes, businesses, or industries.
2. Cooling Method: Oil-CooledThe transformer uses mineral oil or synthetic insulating oil for:
Cooling: Dissipates heat from the windings and core.
Insulation: Provides electrical insulation between internal components.
It usually has radiators, cooling fins, or even fans to aid in heat dissipation.
OLTC adjusts the transformer’s output voltage without interrupting the load.
It compensates for voltage variations in the supply network due to:
Load changes
Line losses
Network voltage fluctuations
OLTC changes the number of turns in the transformer winding.
This is done by switching taps on the high-voltage winding while the transformer is in operation.
Uses arcing contacts, resistors, or reactors to manage voltage steps safely.
Controlled either manually, remotely, or via automatic voltage control relays (AVRs).
| Component | Description |
|---|---|
| Core | Laminated steel core for magnetic flux |
| Windings | Copper or aluminum conductors for HV/LV sides |
| Transformer Oil | Cools and insulates the internal parts |
| Tank & Radiators | Steel tank filled with oil and cooling radiators/fins |
| OLTC Unit | Tap changing switch, motor drive, and control panel |
| Conservator Tank | Holds reserve oil and manages oil expansion |
| Breather (Silica Gel) | Removes moisture from the air entering the conservator |
| Buchholz Relay | Gas-accumulation protection (in larger transformers) |
| Temperature Gauges & Oil Level Indicators | Monitoring instruments |
Utility power distribution substations
Industrial plants
Large commercial buildings
Renewable energy (solar/wind farms)
₹ 2608000 / Piece Get Latest Price
| Power | 1000 KVA |
| KVA Capicity | 1000 KVA |
| Energy Lable | As Per Energy Efficient Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Tapechainger | OlTC |
| Tapping Range in + | 10 % |
| Tapping Range in - | 10 % |
| 50% Losses | 2790 W |
| 100% Losses | 7700 W |
| Impidence | 5 % |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
| Types of Cooling | ONAN |
Minimum order quantity: 1 Piece
An Oil-Cooled Distribution Transformer with OLTC (On-Load Tap Changer) is a critical component in power distribution systems. Here's a clear and structured description of this equipment:
Oil-Cooled Distribution Transformer with OLTC 1. Basic FunctionA distribution transformer steps down high-voltage electricity (from transmission lines) to a lower voltage suitable for local distribution to homes, businesses, or industries.
2. Cooling Method: Oil-CooledThe transformer uses mineral oil or synthetic insulating oil for:
Cooling: Dissipates heat from the windings and core.
Insulation: Provides electrical insulation between internal components.
It usually has radiators, cooling fins, or even fans to aid in heat dissipation.
OLTC adjusts the transformer’s output voltage without interrupting the load.
It compensates for voltage variations in the supply network due to:
Load changes
Line losses
Network voltage fluctuations
OLTC changes the number of turns in the transformer winding.
This is done by switching taps on the high-voltage winding while the transformer is in operation.
Uses arcing contacts, resistors, or reactors to manage voltage steps safely.
Controlled either manually, remotely, or via automatic voltage control relays (AVRs).
| Component | Description |
|---|---|
| Core | Laminated steel core for magnetic flux |
| Windings | Copper or aluminum conductors for HV/LV sides |
| Transformer Oil | Cools and insulates the internal parts |
| Tank & Radiators | Steel tank filled with oil and cooling radiators/fins |
| OLTC Unit | Tap changing switch, motor drive, and control panel |
| Conservator Tank | Holds reserve oil and manages oil expansion |
| Breather (Silica Gel) | Removes moisture from the air entering the conservator |
| Buchholz Relay | Gas-accumulation protection (in larger transformers) |
| Temperature Gauges & Oil Level Indicators | Monitoring instruments |
Utility power distribution substations
Industrial plants
Large commercial buildings
Renewable energy (solar/wind farms)
₹ 335000 / Piece Get Latest Price
| Primary Voltage | 33 kV |
| Cooling Type | Oil Filled |
| No Of Phase | Three |
| Service and Duty | Continuous |
| Nominal Voltage | 11 KV / 22 KV / 33 KV |
| Full Load Losses | As per BIS Lavel |
| LV Voltage | 0.433 KV |
| Temprature rise Oil And Winding | 50 / 55 degree |
| No Load Losses | As Per Costumer Requirement |
| Taping | As Per Costumer Requirement |
| Rated KVA | KVA Capacity As Per requirement |
| Load Losses At Half Load | As Per BIS Lavel |
| Instalaton | Indoor / Outdoor |
| Impedance | As Per BIS |
| Vector Group | As Per Costumer Requirement |
| Orientation Of HV And LV | General 180 Degree And If Required 90 Degree |
| Type Of Cooling | Air cooled / Oil Cooled |
The transformers will be suitable for outdoor installation with three phase, 50Hz, 11 kV system in which the neutral is effectively earthed and theyshould be suitable for service with fluctuations in supply voltage up to plus 12.5% to minus 12.5%.
Range : The standard ratings shall be 250, 315, 400, 500, 630, 800, 1000, 1250, 1500, 1600, 2000 and 2500 KVA for 11 kV distribution transformers.
Vector Group : As per customer’s custom requirement.
Core : The core shall be stack / wound type of high grade cold rolled grain oriented annealed steel lamination having low loss and good grain properties, coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise.
Core Test : The preliminary core loss test will be conducted before passing to the assembly stage.
Winding : HV and LV windings shall be wound from Super Enamel covered /Double Paper covered, aluminum /copper conductor/ foil.
Tapings : For ratings higher than 250 kVA, tapping shall be provided if required by the purchaser on the higher voltage winding for variation of HV voltage within range of (+) 5.0 % to (-)15.0 % in steps of 2.5%.
OIL : The insulating oil shall comply with the requirements of IS 335 or BS 148 Oil shall be filtered and tested for break down voltage (BDV) and moisture content before filling. The oil shall be filled under vacuum.
Tank :The transformer tank is of robust construction rectangular in shape and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for top and bottom and 4 mm side plate.
Conservator : The capacity of a conservator tank is designed keeping in Observation the total quantity of oil and its contraction and expansion due to temperature variations The total volume of conservator shall be such as to contain10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator.
BUSHINGS: for 11 kV, 17.5 kV class bushings and for 0.433 kV, 1.1 kV class bushings shall be used.
TESTING : We are conduct all routin test.
₹ 335000 / Piece Get Latest Price
| Material | Stainless Steel |
| Rated KVA | As costumer requirement(250 KVA To 2500 KVA) |
| Taping | As Per Costumer Requirement( Generally +5% To -5%) |
| Impedance | As Per BIS |
| No Load Losses | As Per Costumer Requirement |
| Full Load Losses | As per BIS Lavel |
| Load Losses At Half Load | As Per BIS Lavel |
| No Load Current | Less Then 3 Percentage |
| No Of Phase | Three |
| Nominal Voltage | 11 KV / 22 KV / 33 KV |
| Secondary Voltage | As Per Costumer Requirement (Generally 433 Voltage) |
| Instalaton | Indoor / Outdoor |
| Type Of Cooling | Oil Cooled |
| Phase Group | As Per vector group |
| Orientation Of HV And LV | General 180 Degree And If Required 90 Degree |
| Temprature rise Oil And Winding | 50 / 55 degree |
The transformers will be suitable for outdoor installation with three phase, 50Hz, 11 kV system in which the neutral is effectively earthed and theyshould be suitable for service with fluctuations in supply voltage up to plus 12.5% to minus 12.5%.
Range : The standard ratings shall be 250, 315, 400, 500, 630, 800, 1000, 1250, 1500, 1600, 2000 and 2500 KVA for 11 kV distribution transformers.
Vector Group : As per customer’s custom requirement.
Core : The core shall be stack / wound type of high grade cold rolled grain oriented annealed steel lamination having low loss and good grain properties, coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise.
Core Test : The preliminary core loss test will be conducted before passing to the assembly stage.
Winding : HV and LV windings shall be wound from Super Enamel covered /Double Paper covered, aluminum /copper conductor/ foil.
Tapings : For ratings higher than 250 kVA, tapping shall be provided if required by the purchaser on the higher voltage winding for variation of HV voltage within range of (+) 5.0 % to (-)15.0 % in steps of 2.5%.
OIL : The insulating oil shall comply with the requirements of IS 335 or BS 148 Oil shall be filtered and tested for break down voltage (BDV) and moisture content before filling. The oil shall be filled under vacuum.
Tank :The transformer tank is of robust construction rectangular in shape and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for top and bottom and 4 mm side plate.
Conservator : The capacity of a conservator tank is designed keeping in Observation the total quantity of oil and its contraction and expansion due to temperature variations The total volume of conservator shall be such as to contain10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator.
BUSHINGS: for 11 kV, 17.5 kV class bushings and for 0.433 kV, 1.1 kV class bushings shall be used.
TESTING : We are conduct all routin test.
₹ 600000 / Piece Get Latest Price
| KVA | As per costumer Requirement (250 KVA To 2500 KVA |
| Impedance | As Per BIS |
| No Load Losses | As Per Costumer Requirement |
| No Load current | Less then 3 Percent of Full load current |
| Full load losses | As Per BIS Lavel |
| No Load Losses at Half Load | As per BIS Lavel |
| Nominal Voltage | 11 KV / 22 KV / 33 KV |
| Secondary Voltage | As Per Costumer Requirement (Generally 433 Voltage) |
| No Of Phase | Three |
| Type Of Cooling | Oil Cooled |
| Installation | indoor / Outdoor |
| Orientation Of HV And LV | General 180 Degree And If Required 90 Degree |
| Taping | As Per Costumer Requirement( Generally +5% To -5%) |
| Phase Group | As Per vector group |
The transformers will be suitable for outdoor installation with three phase, 50Hz, 11 kV system in which the neutral is effectively earthed and theyshould be suitable for service with fluctuations in supply voltage up to plus 12.5% to minus 12.5%.
Range :The standard ratings shall be 250, 315, 400, 500, 630, 800, 1000, 1250, 1500, 1600, 2000 and 2500 KVA for 11 kV distribution transformers.
Vector Group : As percustomer’s custom requirement.
Core : The core shall be stack / wound type of high grade cold rolled grain oriented annealed steel lamination having low loss and good grain properties, coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise.
Core Test : The preliminary core loss test will be conducted before passing to the assembly stage.
Winding : HV and LV windings shall be wound from Super Enamel covered /Double Paper covered, aluminum /copper conductor/ foil.
Tapings : For ratings higher than 250 kVA, tapping shall be provided if required by the purchaser on the higher voltage winding for variation of HV voltage within range of (+) 5.0 % to (-)15.0 % in steps of 2.5%.
OIL : The insulating oil shall comply with the requirements of IS 335 or BS 148 Oil shall be filtered and tested for break down voltage (BDV) and moisture content before filling. The oil shall be filled under vacuum.
Tank :The transformer tank is of robust construction rectangular in shape and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for top and bottom and 4 mm side plate.
Conservator : The capacity of a conservator tank is designed keeping in Observation the total quantity of oil and its contraction and expansion due to temperature variations The total volume of conservator shall be such as to contain10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator.
BUSHINGS: for 11 kV, 17.5 kV class bushings and for 0.433 kV, 1.1 kV class bushings shall be used.
TESTING : We are conduct all routin test.
₹ 1592000 / Piece Get Latest Price
| Power | 630 kva |
| KVA capicity | 630 Kva |
| Energy Lable | Buro of indian standard Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Tapechainger | OCTC |
| Tapping Range | +/- 5% |
| 50% Losses | 1860 W |
| 100% Losses | 5300 W |
| Impidence | 4.5 % Talerance +/- 10% (As Per Requirement ) |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
| Types of Cooling | ONAN |
Minimum order quantity: 1 Piece
₹ 1266000 / Piece Get Latest Price
| Power | 315 kva |
| KVA capicity | 315 Kva |
| Energy Lable | Buro of indian standard Level - 1 |
| Voltage ratio | 11 KV , 0.433 KV |
| Number of Phase | 3 Phase |
| Frequency | 50/60 HZ |
| Type of Installation | Indoore / Outdoore |
| Duty Cycle | Contionus |
| Types of Tapechainger | OCTC |
| Tapping Range | +/- 5 % |
| 50% Losses | 1025 W |
| 100% Losses | 3100 W |
| Impidence | 4.5 % Talerance +/- 10% (As Per Requirement ) |
| Type of connection | DYN11 (As Per Requirement ) |
| Tempreture in Oil | 40 Degree |
| Tempreture in Winding | 45 Degree |
| Types of Cooling | ONAN |
Minimum order quantity: 1 Piece
₹ 1400000 / Piece Get Latest Price
| Rated KVA | As costumer requirement(250 KVA To 2500 KVA) |
| Taping | As Per Costumer Requirement( Generally +5% To -5%) |
| Impedance | As Per BIS |
| No Load Losses | As Per Costumer Requirement |
| Full Load Losses | As per BIS Lavel |
| Load Losses At Half Load | As Per BIS Lavel |
| No Load Current | Less Then 3 Percentage |
| No Of Phase | Three |
| Nominal Voltage | 11 KV / 22 KV / 33 KV |
| Secondary Voltage | As Per Costumer Requirement (Generally 433 Voltage) |
| Instalaton | Indoor / Outdoor |
| Type Of Cooling | Oil Cooled |
| Vector Group | As Per Costumer Requirement |
| Orientation Of HV And LV | General 180 Degree And If Required 90 Degree |
| Temprature rise Oil And Winding | 50 / 55 degree |
KAY PEE offers a complete range of power and distribution transformers designed to grant the reliability, durability, and efficiency required in utility, industrial, and commercial applications. KAY PEE 's liquid-filled transformers are manufactured in accordance with the most demanding industry and international standards. Transformers can be used for indoor or outdoor applications and can be provided with off-load and on-load tap changers.
The transformer are manufactured in accordance with IS 2026/1977, IS 1180/2016, IEC 60076 or as per customer’s custom requirement.
The transformers will be suitable for outdoor installation with three phase, 50Hz, 11 kV system in which the neutral is effectively earthed and theyshould be suitable for service with fluctuations in supply voltage up to plus 12.5% to minus 12.5%.
Range : The standard ratings shall be 250, 315, 400, 500, 630, 800, 1000, 1250, 1500, 1600, 2000 and 2500 KVA for 11 kV distribution transformers.
Vector Group : As per customer’s custom requirement.
Core : The core shall be stack / wound type of high grade cold rolled grain oriented annealed steel lamination having low loss and good grain properties, coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise.
Core Test : The preliminary core loss test will be conducted before passing to the assembly stage.
Winding : HV and LV windings shall be wound from Super Enamel covered /Double Paper covered, aluminum /copper conductor/ foil.
Tapings : For ratings higher than 250 kVA, tapping shall be provided if required by the purchaser on the higher voltage winding for variation of HV voltage within range of (+) 5.0 % to (-)15.0 % in steps of 2.5%.
OIL : The insulating oil shall comply with the requirements of IS 335 or BS 148 Oil shall be filtered and tested for break down voltage (BDV) and moisture content before filling. The oil shall be filled under vacuum.
Tank :The transformer tank is of robust construction rectangular in shape and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for top and bottom and 4 mm side plate.
Conservator : The capacity of a conservator tank is designed keeping in Observation the total quantity of oil and its contraction and expansion due to temperature variations The total volume of conservator shall be such as to contain10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator.
BUSHINGS: for 11 kV, 17.5 kV class bushings and for 0.433 kV, 1.1 kV class bushings shall be used.
TESTING : We are conduct all routin test.
₹ 200000 / Piece Get Latest Price
| Make | " KAY PEE " |
| KVA | As Per Customer Requirement ( 10 KVA To 2500 KVA ) |
| No Of Phase | Three |
| Nominal Voltage | 3.3 KV / 6.6 KV / 11 KV / 22 KV / 33 KV |
| Secondary Voltage | As Per Customer Requirement |
| Supply Frequency | 50 / 60 Hz |
| Installation | Indoor / Outdoor |
| Type Of Cooling | Oil Cooled |
| Vector Group | As Per Customer Required |
| Orientation HV and LV | General 180 Degree if Required 90 Degree |
| Temprature Rise Oil and Winding | 60 / 65 Degree |
| Tapping | As Per Costumer Requirement( Generally +5% To -5%) |
| Impedance | As Per Costumer Demand |
| No Load Loss | As Per Costumer Required |
| No Load Current | Less Then 3 Percentage of Rated Current |
| Full Load Losses | As Per IS 2026 |
The transformers will be suitable for outdoor installation with three phase, 50Hz, 11 kV system in which the neutral is effectively earthed and theyshould be suitable for service with fluctuations in supply voltage up to plus 12.5% to minus 12.5%.
Range : The standard ratings shall be 250, 315, 400, 500, 630, 800, 1000, 1250, 1500, 1600, 2000 and 2500 KVA for 11 kV distribution transformers.
Vector Group : As per customer’s custom requirement.
Core : The core shall be stack / wound type of high grade cold rolled grain oriented annealed steel lamination having low loss and good grain properties, coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise.
Core Test : The preliminary core loss test will be conducted before passing to the assembly stage.
Winding : HV and LV windings shall be wound from Super Enamel covered /Double Paper covered, aluminum /copper conductor/ foil.
Tapings : For ratings higher than 250 kVA, tapping shall be provided if required by the purchaser on the higher voltage winding for variation of HV voltage within range of (+) 5.0 % to (-)15.0 % in steps of 2.5%.
OIL : The insulating oil shall comply with the requirements of IS 335 or BS 148 Oil shall be filtered and tested for break down voltage (BDV) and moisture content before filling. The oil shall be filled under vacuum.
Tank :The transformer tank is of robust construction rectangular in shape and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for top and bottom and 4 mm side plate.
Conservator : The capacity of a conservator tank is designed keeping in Observation the total quantity of oil and its contraction and expansion due to temperature variations The total volume of conservator shall be such as to contain10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator.
BUSHINGS: for 11 kV, 17.5 kV class bushings and for 0.433 kV, 1.1 kV class bushings shall be used.
TESTING : We are conduct all routin test.
₹ 335000 / Piece Get Latest Price
| Make | " KAY PEE " |
| Orientatin of HV And LV | General 180 degree If required 90 Degree |
| Temprature Rise Oil And Winding | 60 / 65 Degree |
| Tapping | As Per Costumer Requirement( Generally +5% To -5%) |
| Impedance | As Per Costumer Demand |
| No Load Loss | As Per Costumer Required |
| No load Current | Less Then 3 Percentage of rated Current |
| Full Load Losses | As Per IS 2026 |
| KVA | As Per Costumer Requirement ( 10 KVA To 2500 KVA ) |
| No Of Phase | Three |
| Nominal Voltage | 11 KV / 22 KV / 33 KV |
| Secondary Voltage | As Per Costumer Requirement (Generally 433 Voltage) |
| Supply Frequency | 50 / 60 Hz |
| Installation | Indoor / Outdoor |
| Type Of Cooling | Oil Cooled |
| Vector Group | As Per Costumer Required |
The transformers will be suitable for outdoor installation with three phase, 50Hz, 11 kV system in which the neutral is effectively earthed and theyshould be suitable for service with fluctuations in supply voltage up to plus 12.5% to minus 12.5%.
Range :The standard ratings shall be 250, 315, 400, 500, 630, 800, 1000, 1250, 1500, 1600, 2000 and 2500 KVA for 11 kV distribution transformers.
Vector Group : As percustomer’s custom requirement.
Core : The core shall be stack / wound type of high grade cold rolled grain oriented annealed steel lamination having low loss and good grain properties, coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise.
Core Test : The preliminary core loss test will be conducted before passing to the assembly stage.
Winding : HV and LV windings shall be wound from Super Enamel covered /Double Paper covered, aluminum /copper conductor/ foil.
Tapings : For ratings higher than 250 kVA, tapping shall be provided if required by the purchaser on the higher voltage winding for variation of HV voltage within range of (+) 5.0 % to (-)15.0 % in steps of 2.5%.
OIL : The insulating oil shall comply with the requirements of IS 335 or BS 148 Oil shall be filtered and tested for break down voltage (BDV) and moisture content before filling. The oil shall be filled under vacuum.
Tank :The transformer tank is of robust construction rectangular in shape and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for top and bottom and 4 mm side plate.
Conservator : The capacity of a conservator tank is designed keeping in Observation the total quantity of oil and its contraction and expansion due to temperature variations The total volume of conservator shall be such as to contain10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator.
BUSHINGS: for 11 kV, 17.5 kV class bushings and for 0.433 kV, 1.1 kV class bushings shall be used.
TESTING : We are conduct all routin test.
₹ 775000 / Piece Get Latest Price
| Material | Copper |
| Rated KVA | 250 KVA |
| No Of Phase | Three |
| Nominal Voltage | 11 KV / 22 KV / 33 KV |
| Secondary Voltage | As Per Costumer Requirement (Generally 433 Voltage) |
| Instalaton | Indoor / Outdoor |
| Type Of Cooling | Oil Cooled |
| Phase Group | As Per vector group |
| Orientation Of HV And LV | General 180 Degree And If Required 90 Degree |
| Temprature rise Oil And Winding | 40 / 45 degree |
| Taping | As Per Costumer Requirement( Generally +5% To -5%) |
| percentage Impedance | As Per BIS |
| No Load Losses | As Per Costumer Requirement |
| No Load current | Less then 3 Percent of Full load current |
| Full load losses | As Per BIS Lavel |
| Load Losses At half Load | As per BIS lavel |
Minimum order quantity: 1 Piece
The transformers will be suitable for outdoor installation with three phase, 50Hz, 11 kV system in which the neutral is effectively earthed and theyshould be suitable for service with fluctuations in supply voltage up to plus 12.5% to minus 12.5%.
Range : The standard ratings shall be 250, 315, 400, 500, 630, 800, 1000, 1250, 1500, 1600, 2000 and 2500 KVA for 11 kV distribution transformers.
Vector Group : As per customer’s custom requirement.
Core : The core shall be stack / wound type of high grade cold rolled grain oriented annealed steel lamination having low loss and good grain properties, coated with hot oil proof insulation, bolted together and to the frames firmly to prevent vibration or noise.
Core Test : The preliminary core loss test will be conducted before passing to the assembly stage.
Winding : HV and LV windings shall be wound from Super Enamel covered /Double Paper covered, aluminum /copper conductor/ foil.
Tapings : For ratings higher than 250 kVA, tapping shall be provided if required by the purchaser on the higher voltage winding for variation of HV voltage within range of (+) 5.0 % to (-)15.0 % in steps of 2.5%.
OIL : The insulating oil shall comply with the requirements of IS 335 or BS 148 Oil shall be filtered and tested for break down voltage (BDV) and moisture content before filling. The oil shall be filled under vacuum.
Tank :The transformer tank is of robust construction rectangular in shape and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for top and bottom and 4 mm side plate.
Conservator : The capacity of a conservator tank is designed keeping in Observation the total quantity of oil and its contraction and expansion due to temperature variations The total volume of conservator shall be such as to contain10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator.
BUSHINGS: for 11 kV, 17.5 kV class bushings and for 0.433 kV, 1.1 kV class bushings shall be used.
TESTING : We are conduct all routin test.